  series am 30k-z 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6 832) f 051e r 8.f 1 of 4 north america only features: ? wide input 2:1 range ? adjustable output voltage ? full smd technology ? remote on/off function ? 1500 vdc isolation ? over current, voltage, & temperature protection ? efficiency up to 91% ? soft start models : single output model input C voltage (v) output voltage (v) output current max (a) isolation (vdc) max capacitive load (uf) efficiency (%) am30k - 1203sz 9 - 18 3.3 5.5 1500 15000 83 am30k - 1205sz 9 - 18 5 5.0 1500 10000 86 am30k - 1212sz 9 - 18 12 2.5 1500 2200 90 am30k - 1215sz 9 - 18 15 2.0 1500 1000 90 am30k - 2403sz 18 - 36 3.3 5.5 1500 15000 84 am30k - 2405sz 18 - 36 5 5.0 1500 10000 87 am30k - 2412sz 18 - 36 12 2.5 1500 2200 91 am30k - 2415sz 18 - 36 15 2.0 1500 1000 91 am30k - 4803sz 36 - 75 3.3 5.5 1500 15000 84 am30k - 4805sz 36 - 75 5 5.0 1500 10000 87 am30k - 48 12sz 36 - 75 12 2.5 1500 2200 91 am30k - 4815sz 36 - 75 15 2.0 1500 1000 91 models : dual output model input C voltage (v) output voltage (v) output current max (a) isolation (vdc) max capacitive load (uf) efficiency (%) am30k - 1212dz 9 - 18 12 1.25 1500 100 0 90 am30k - 1215dz 9 - 18 15 1.0 1500 680 90 am30k - 2412dz 18 - 36 12 1.25 1500 1000 91 am30k - 2415dz 18 - 36 15 1.0 1500 680 91 am30k - 4812dz 36 - 75 12 1.25 1500 1000 90 am30k - 4815dz 36 - 75 15 1.0 1500 680 90 note: all specifications in this dat asheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. input specifications input specifications nominal typical maximum units voltage range 12 9 - 18 vdc 24 18 - 36 48 36 - 75 filter (pi) network start up time 20 ms absolute maximum rated input voltage 12 25 vdc 24 50 48 100 peak input voltage time 100 ms on/off control on C high or open (2.5v to 5.5v) ; off C low ( - 0.7v to 0.8v or short circuit between pin 2 & 3) isolation specifications parameters conditions typical rated units tested i/o voltage 3 sec 1500 vdc resistance 1000 mohm capacitance 1200 pf
series am 30k-z 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6 832) f 051e r 8.f 2 of 4 north america only output specifications output specifications conditions typical maximum units voltage accuracy 5 % voltage balance (dual output model) balanced load 5 % over voltage protection 125 % over current protection 120 % short circuit protection continuous short circuit restart auto recovery line voltage regulation (single) h l - ll 5 % line voltage regulation (dual) hl - ll 5 % load voltage regulation (single) 10% to 100% load 0.5 % load voltage regulation (dual) 10% to 100% load 0.5 % temperature coefficient 0.02 %/ o c ripple & noise at 20mhz bandwidth 75 m vp - p voltage adjustment range 10 % general specifications safety specifications standards agency approvals ce safety iec/en 60950 - 1 en55022 class a en55022 class a en61000 - 4 - 2 perf. criteria b en61000 - 4 - 3 perf. criteria a en61000 - 4 - 4 perf. criteria b en61000 - 4 - 5 perf. criteria b en61000 - 4 - 6 perf. criteria a en61000 - 4 - 8 perf. criteria a input specifications conditions typical maximum units switching frequency 100 % load 270 khz operating temperature with drating above 60 o c (see graph below) - 40 to +85 o c storage temperature - 40 to +125 o c max case temperature 100 cooling free air convection humidity 95 % over temperature protection 110 case material nickel - coated copper and epoxy (ul94v - 0 rated) weight 48 g dimensions (l x w x h) 2.00 x1.60 x0.40 inches 50.8 0 x 40.6 0 x 10.2 0 mm mtbf >1000000 hrs calculated using mil - hdbk - 217 f at +25 o c
series am 30k-z 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6 832) f 051e r 8.f 3 of 4 north america only pin out specifications pin single dual 1 +vin +vin 2 - vin - vin 3 on/off control on/off co ntrol 4 no pin +vout 5 +vout com 6 - vout - vout 7 trim trim dimensions 1 5.08 (0.20) 7.62 (0.30) 17.78 (0.70) 5.10 (0.20) 5.10 (0.20) 2 3 4 5 6 7 10.16 (0.40) 10.16 (0.40) 10.16 (0.40) 10.16 (0.40) bottom view 50.80 (2.00) 40.60 (1.60) 10.16 (0.40) ? 1.00 (0.04) printed face 2.54 (0.10) 5.08 (0.20) 45.72 (1.80) case tolerance 0.50 (0.02) pin pitch tolerance 0.35 (0.014) dimensions mm (inch) built-in stand-offs to ease pcb cleaning trimming
series am 30k-z 30 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6 832) f 051e r 8.f 4 of 4 north america only derating free air convection - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 safe operating area output power (%) 85 ambient temperature o c 60 c o control on/off pin connection example: note a: an external filter capac itor is required if the module has to meet en61000 - 4- 4 and en61000 - 4- 5. the filter capacitor aimtec suggests: 1000uf, 100v. note b: input filter components (c1, c2, l) are used to help meet conducted emissions requirement for the module. these components sh ould be mounted as close as possible to the module; and all leads should be min imized to decrease radiated noise. note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the mo st current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured a t an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of pu blishing this document. cas numbers and other limited information are considered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this da tasheet. 7. warranty is in accordance with aimtecs standard terms of sale available at www.aimtec.com. models c1 l c2 c3 am30k - 12xxxz 330 f, 100v 12h 100, 100v n/a am30k - 24xxxz 330 f, 100v 12h 100, 100v n/a am30k - 48xxxz 330 f , 100v 12h 100, 100v 1000pf, 2000v


▲Up To Search▲   

 
Price & Availability of AM30K-4812DZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X